Skip to main content
Back

Cardiac Anatomy, Electrophysiology, and EKG Interpretation: Study Guide Chapters 1-6

Study Guide - Smart Notes

Tailored notes based on your materials, expanded with key definitions, examples, and context.

Cardiac Anatomy and Physiology

Layers of the Heart

The heart is composed of three distinct layers, each with specialized functions that contribute to its overall performance as a blood pump.

  • Epicardium: Outermost layer; houses the coronary arteries, providing blood supply to the heart muscle.

  • Myocardium: Middle muscular layer; responsible for contraction and pumping blood. Damaged during myocardial infarction.

  • Endocardium: Innermost layer; lines the chambers, forms heart valves, and contains the conduction system. Watertight to prevent blood leakage.

Example: During a heart attack, the myocardium is the layer most affected.

Heart Chambers and Oxygenation Status

The heart has four chambers, each playing a role in blood circulation and oxygenation.

  • Right Atrium: Receives deoxygenated blood (60-75% O2 saturation).

  • Right Ventricle: Pumps deoxygenated blood to the lungs.

  • Left Atrium: Receives oxygenated blood from the lungs (~100% O2 saturation).

  • Left Ventricle: Pumps oxygenated blood to the body.

Heart Valves

Valves ensure unidirectional blood flow and prevent backflow.

  • Atrioventricular (AV) Valves: Tricuspid (right), Mitral/Bicuspid (left).

  • Semilunar Valves: Pulmonic (right), Aortic (left).

Function: Valves open/close based on pressure changes, directing blood flow.

Great Vessels

  • Superior Vena Cava (SVC): Returns deoxygenated blood from upper body.

  • Inferior Vena Cava (IVC): Returns deoxygenated blood from lower body.

  • Pulmonary Artery: Carries deoxygenated blood to lungs.

  • Pulmonary Veins: Carry oxygenated blood to left atrium.

  • Aorta: Distributes oxygenated blood to systemic circulation.

Blood Flow Through the Heart

Blood flow involves both systemic and cardiac circulation:

  • Systemic: Aorta → arteries → capillaries (oxygen delivery) → veins → vena cava.

  • Cardiac: Coronary arteries supply myocardium; coronary veins return deoxygenated blood to right atrium.

The Cardiac Cycle

The cardiac cycle consists of diastole (relaxation) and systole (contraction):

  • Diastole: Rapid-filling, diastasis, atrial kick.

  • Systole: Isovolumetric contraction, ventricular ejection, protodiastole, isovolumetric relaxation.

Coronary Arteries

  • Left Anterior Descending (LAD): Supplies anterior left ventricle and septum.

  • Circumflex: Supplies left atrium, lateral and posterior left ventricle.

  • Right Coronary Artery (RCA): Supplies right atrium, right ventricle, and posterior septum.

Types of Cardiac Cells

  • Contractile Cells: Responsible for heart muscle contraction.

  • Conduction System Cells: Generate and conduct electrical impulses.

Nervous Control of the Heart

  • Sympathetic: Increases heart rate and blood pressure (fight-or-flight).

  • Parasympathetic: Decreases heart rate and blood pressure (rest-and-digest).

Electrophysiology

Polarized, Depolarization, and Repolarization

  • Polarized: Cell at rest, negative inside.

  • Depolarization: Cell becomes positive inside, triggers contraction.

  • Repolarization: Cell returns to negative, triggers relaxation.

Electrical Impulses and Ion Movement

  • Resting: More K+ inside, Na+ outside.

  • Depolarization: Na+ rushes in, K+ leaks out.

  • Repolarization: Na+ pumped out, K+ in.

Action Potential Phases

  • Phase 4: Resting (negative inside).

  • Phase 0: Depolarization (positive inside).

  • Phases 1 & 2: Early repolarization & plateau (Ca2+ influx).

  • Phase 3: Rapid repolarization (K+ efflux).

Refractory Periods

Period

Definition

Implication

Absolute

No new action potential possible

Ensures one-way propagation

Relative

Possible with strong stimulus

Regulates firing frequency

Supernormal

Possible with weak stimulus

Risk of abnormal rhythms

EKG Interpretation

EKG Waves and Segments

  • P Wave: Atrial depolarization.

  • QRS Complex: Ventricular depolarization.

  • T Wave: Ventricular repolarization.

  • PR Segment: Flat line after P wave, before QRS.

  • ST Segment: Flat line after QRS, before T wave.

Labeling a Rhythm Strip

  • P wave, PR segment, PR interval, QRS complex (Q, R, S waves), ST segment, T wave, QT interval.

Heart Walls and Corresponding Leads

Wall

Leads

Anterior

V2, V3, V4

Lateral

I, aVL, V5, V6

Inferior

II, III, aVF

Septal

V1, V2

Posterior

V7, V8, V9 (reciprocal changes in V1-V3)

EKG Paper Delineations

  • Small box: 0.04 sec, 0.1 mV

  • Large box: 0.20 sec, 0.5 mV

Pacemakers of the Heart

Pacemaker

Location

Rate (bpm)

SA Node

Right atrium

60–100

AV Node

AV junction

40–60

Purkinje Fibers

Ventricles

20–40

Cardiac Impulse Conduction Pathway

  • SA node → Atrial conducting fibers → AV node → Bundle of His → Right & Left bundle branches → Purkinje fibers

Characteristics of Cardiac Cells

  • Automaticity: Self-initiating impulse

  • Conductivity: Transmitting impulse

  • Excitability: Responding to stimulus

  • Contractility: Contracting to pump blood

Escape vs. Usurpation

  • Escape: Backup pacemaker takes over when primary fails (slower rhythm).

  • Usurpation: Lower pacemaker overrides primary by firing faster (faster rhythm).

Rhythm Strip vs. 12-Lead EKG

  • Rhythm Strip: Single lead, focuses on rhythm and rate.

  • 12-Lead EKG: Multiple leads, provides full diagnostic picture.

Lead Morphology and Placement

Electrode and Lead Definitions

  • Electrode: Sensor placed on skin to detect electrical signals.

  • Lead: View or angle of heart's electrical activity, created from electrodes.

Bipolar and Unipolar Leads

  • Bipolar Leads: I, II, III (measure between two points).

  • Unipolar Augmented Leads: aVR, aVL, aVF (single positive electrode, reference from other electrodes).

Einthoven’s Law

Einthoven’s Law states:

  • Used to verify correct lead placement and EKG accuracy.

Einthoven’s Triangle

Einthoven’s triangle visualizes limb electrode placement and bipolar leads.

Einthoven's triangle diagram showing limb electrode placement and lead directions

Precordial Leads

Lead

Location

V1

4th ICS, right sternal border

V2

4th ICS, left sternal border

V3

Between V2 and V4

V4

5th ICS, midclavicular line

V5

5th ICS, anterior axillary line

V6

5th ICS, midaxillary line

Continuous Monitoring Leads

  • Lead II: Excellent for atrial and ventricular activity.

  • V1/MCL1: Useful for wide QRS complexes.

Electrocardiographic Truths

  • Impulse toward positive electrode: positive QRS.

  • Impulse away from positive electrode: negative QRS.

  • Impulse at right angle: isoelectric complex.

Normal QRS Complex Deflections in 12-Lead EKG

  • Leads I, II, III, aVL, aVF: Positive QRS.

  • aVR: Negative QRS.

  • V1, V2: Negative QRS.

  • V3, V4: Isoelectric.

  • V5, V6: Positive QRS.

Diagram showing QRS complex deflections in the 12 EKG leads

Technical Aspects of the EKG

EKG Machine Control Features

  • Chart Speed: Controls paper speed (standard 25 mm/s).

  • Gain: Adjusts wave height (standard 10 mm/mV).

  • Frequency Response: Filters noise/artifact.

Macroshock vs. Microshock

  • Macroshock: High-voltage shock, risk from faulty equipment.

  • Microshock: Low-voltage, dangerous for patients with internal devices.

EKG Artifacts and Troubleshooting

Artifact

Appearance

Cause

Somatic Tremors

Jittery, shaky tracing

Patient movement

Baseline Sway

Wandering baseline

Breathing, loose electrodes

60 Cycle Interference

Thick, fuzzy baseline

Electrical devices

Broken Recording

Erratic, interrupted tracing

Loose wires/electrodes

  • Troubleshoot by checking patient, electrodes, wires, and reducing interference.

Differentiating Artifact from Real Rhythm

  • Check consistency across leads, waveform shape, patient activity, baseline stability, and physiological plausibility.

Calculating Heart Rate

Heart Rate Definition

  • Number of QRS complexes per minute (bpm).

Heart Rate Calculation Methods

Method

How to Calculate

6-Second Strip

Count QRS in 6 seconds, multiply by 10

Memory/300 Method

Count large boxes between QRS, use sequence: 300, 150, 100, 75, 60, 50, 43, 37, 33, 30

1500/Little Block Method

Count small boxes between QRS, divide 1500 by that number

Formula:

Types of Rhythm Regularity

  • Regular: Consistent R-R intervals.

  • Regular but Interrupted: Premature beats or pauses.

  • Irregular: Unpredictable R-R intervals.

Heart Rate Calculation for Rhythm Types

  • Regular: Use 300 or 1500 methods.

  • Irregular: Use 6-second strip method.

  • Interrupted: Calculate on regular portions, ignore interruptions.

Rhythm Strip Interpretation

Steps to Rhythm Identification

  1. Check for QRS complexes.

  2. Determine regularity (R-R intervals).

  3. Calculate heart rate.

  4. Identify and describe P waves.

  5. Measure PR interval (0.12–0.20 sec).

  6. Measure QRS complex (<0.12 sec).

Criteria for Normal Sinus Rhythm (NSR)

  • Regular rhythm (R-R intervals consistent).

  • Rate: 60–100 bpm.

  • P wave before every QRS.

  • QRS follows every P wave.

  • PR interval: 0.12–0.20 sec.

  • QRS: <0.12 sec.

  • QT interval: 0.36–0.40 sec (varies with rate).

Arrhythmia

  • Any rhythm outside NSR criteria (except rate).

  • Ectopy: Cell firing outside normal conduction system.

  • Types: Irregular rhythms, premature beats, conduction blocks, abnormal intervals.

Example: Atrial fibrillation lacks P waves and has a wavy baseline, reducing cardiac output.

Additional info: Images included are directly relevant to Einthoven's triangle and QRS complex deflections in the 12-lead EKG, reinforcing the explanation of lead placement and morphology.