BackCh. 18 B. The Cardiovascular System: Electrical and Mechanical Events of the Heart
Study Guide - Smart Notes
Tailored notes based on your materials, expanded with key definitions, examples, and context.
The Cardiovascular System: Electrical and Mechanical Events of the Heart
Electrical Events of the Heart
The heart's rhythmic contractions are initiated and coordinated by its intrinsic conduction system, which operates independently of the nervous system but can be modulated by autonomic input. This system ensures the heart beats in a coordinated and efficient manner.
Intrinsic Conduction System
Gap Junctions: Specialized connections between cardiac muscle cells that allow for rapid transmission of electrical impulses.
Autorhythmic Cells: Noncontractile cells that generate and distribute action potentials, setting the basic rhythm of the heart.
Pacemaker Cells and Action Potentials
Pacemaker cells, primarily located in the sinoatrial (SA) node, have unstable resting membrane potentials, known as pacemaker potentials. Their action potential consists of three main phases:
Pacemaker Potential: Slow depolarization due to opening of Na+ channels and closing of K+ channels.
Depolarization: Rapid influx of Ca2+ once threshold is reached, causing the rising phase of the action potential.
Repolarization: Opening of K+ channels, allowing K+ efflux and return to a more negative membrane potential.



Sequence of Excitation
The conduction system passes impulses through the heart in approximately 0.22 seconds:
Sinoatrial (SA) node
Atrioventricular (AV) node
Atrioventricular (AV) bundle (bundle of His)
Right and left bundle branches
Subendocardial conducting network (Purkinje fibers)




Key Nodes and Pathways
SA Node: Pacemaker in the right atrial wall; initiates impulses at about 75 times per minute (sinus rhythm).
AV Node: Located in the inferior interatrial septum; delays impulses by ~0.1 second to allow atrial contraction before ventricular contraction.
AV Bundle (Bundle of His): Only electrical connection between atria and ventricles.
Bundle Branches: Carry impulses through the interventricular septum toward the apex.
Purkinje Fibers: Complete the pathway into the ventricular walls, ensuring coordinated contraction.
Clinical Correlations: Conduction System Disorders
Arrhythmias: Irregular heart rhythms due to defects in the conduction system.
Fibrillation: Rapid, irregular contractions; can be fatal if not corrected by defibrillation.
Ectopic Focus: Abnormal pacemaker activity, often due to a defective SA node.
Heart Block: Impaired conduction through the AV node; may require an artificial pacemaker.
Extrinsic Innervation of the Heart
The autonomic nervous system (ANS) modulates heart rate and force:
Sympathetic Stimulation: Increases heart rate and contractility via the cardioacceleratory center.
Parasympathetic Stimulation: Decreases heart rate via the vagus nerve and the cardioinhibitory center.

Action Potentials of Contractile Cardiac Muscle Cells
Contractile cardiac muscle fibers are responsible for the heart's pumping action. Their action potentials differ from skeletal muscle due to the presence of a plateau phase.
Depolarization: Rapid Na+ influx through voltage-gated channels.
Plateau: Slow Ca2+ influx keeps the cell depolarized.
Repolarization: Ca2+ channels inactivate and K+ channels open, restoring resting potential.



Duration: Cardiac muscle action potentials last about 200 ms, much longer than skeletal muscle (1–2 ms).
Benefit: Longer refractory period prevents tetanus and ensures efficient blood ejection.
Electrocardiography (ECG/EKG)
An electrocardiogram (ECG) records the electrical activity of the heart and is a composite of all action potentials occurring at a given time. It is a crucial diagnostic tool for assessing heart function.
P wave: Atrial depolarization (SA node and atria).
QRS complex: Ventricular depolarization and atrial repolarization.
T wave: Ventricular repolarization.
P-R interval: Start of atrial to start of ventricular excitation.
S-T segment: Entire ventricular myocardium depolarized.
Q-T interval: Start of ventricular depolarization to end of repolarization.

Clinical Correlations: ECG Abnormalities
Enlarged R waves: May indicate ventricular hypertrophy.
Elevated/Depressed S-T segment: Indicates cardiac ischemia.
Prolonged Q-T interval: Suggests repolarization abnormalities and risk of arrhythmias.




Mechanical Events of the Heart: The Cardiac Cycle
The cardiac cycle describes the sequence of mechanical events during one heartbeat, including periods of contraction (systole) and relaxation (diastole). These events are tightly coupled to the electrical activity of the heart.
Systole: Contraction phase, blood is ejected from chambers.
Diastole: Relaxation phase, chambers fill with blood.
Phases of the Cardiac Cycle
Ventricular Filling (mid-to-late diastole): AV valves open, 80% of blood flows passively into ventricles, atrial contraction delivers remaining 20% (EDV measured here).
Isovolumetric Contraction: Ventricles contract with all valves closed, pressure rises until SL valves open.
Ventricular Ejection: SL valves open, blood is ejected into aorta and pulmonary trunk.
Isovolumetric Relaxation (early diastole): Ventricles relax, SL valves close, ESV measured here, cycle repeats.


Heart Sounds
First sound (lub): Closing of AV valves at the start of ventricular systole.
Second sound (dup): Closing of SL valves at the start of ventricular diastole.
Valve sounds can be auscultated at specific thoracic locations.

Clinical Correlations: Heart Murmurs
Incompetent Valve: Fails to close completely, causing backflow and a swishing sound.
Stenotic Valve: Fails to open completely, causing a high-pitched or clicking sound.
Regulation of Cardiac Output
Cardiac output (CO) is the volume of blood pumped by each ventricle per minute. It is a key measure of heart performance and is regulated by several factors.
Formula:
Stroke Volume (SV): Volume of blood pumped per beat ()
Cardiac Reserve: Difference between resting and maximal CO.

Regulation of Stroke Volume
Preload: Degree of stretch of cardiac muscle before contraction (Frank-Starling law).
Contractility: Contractile strength at a given muscle length, increased by sympathetic stimulation and certain hormones.
Afterload: Pressure ventricles must overcome to eject blood (increased in hypertension).

Regulation of Heart Rate
Autonomic Nervous System: Sympathetic increases HR, parasympathetic decreases HR (vagal tone).
Chemicals: Hormones (epinephrine, thyroxine) and ions (Ca2+, K+) affect HR.
Other Factors: Age, gender, exercise, and body temperature.

Clinical Correlations: Cardiac Output Disorders
Congestive Heart Failure (CHF): Inadequate CO due to weakened myocardium, often from coronary atherosclerosis, hypertension, myocardial infarcts, or dilated cardiomyopathy.
Pulmonary Congestion: Left-sided failure, blood backs up in lungs.
Peripheral Congestion: Right-sided failure, blood pools in body organs.
Developmental Aspects of the Heart
The heart develops from mesoderm and begins pumping blood by day 22 of embryonic development. Structural changes lead to a four-chambered heart by day 35.
Sinus Venosus: Forms right atrium, coronary sinus, and SA node.
Atrium: Forms pectinate muscles of atria.
Ventricle: Forms left ventricle.
Bulbus Cordis: Forms aorta, pulmonary trunk, and right ventricle.

Fetal Circulation Adaptations
Foramen Ovale: Connects atria; becomes fossa ovalis after birth.
Ductus Arteriosus: Connects pulmonary trunk to aorta; becomes ligamentum arteriosum after birth.
Congenital Heart Defects
Mixing of Oxygen-Poor and Oxygen-Rich Blood: E.g., septal defects, patent ductus arteriosus.
Narrowed Valves or Vessels: E.g., coarctation of the aorta.
Tetralogy of Fallot: Combination of four defects.

Age-Related Changes
Sclerosis and Thickening of Valves: Leads to murmurs.
Decline in Cardiac Reserve: Reduced efficiency with age.
Fibrosis of Cardiac Muscle: Stiffens heart, increases arrhythmia risk.
Atherosclerosis: Can be mitigated by a healthy diet and exercise.