Capitolo 28, Problema 49

If 75 MW of power at 45 kV (rms) arrives at a town from a generator via transmission lines of total resistance 3.0 Ω, calculate (a) the emf at the generator end of the lines, and (b) the fraction of the power generated that is wasted in the lines.

Guida verificata passo dopo passo
1
Step 1: Start by calculating the current (I) in the transmission lines using the formula for power: \( P = V_{rms} \cdot I \), where \( P \) is the power delivered (75 MW) and \( V_{rms} \) is the root mean square voltage (45 kV). Rearrange the formula to solve for \( I \): \( I = \frac{P}{V_{rms}} \).
Step 2: Calculate the power loss in the transmission lines due to resistance using the formula \( P_{loss} = I^2 \cdot R \), where \( R \) is the total resistance of the transmission lines (3.0 Ω). Substitute the value of \( I \) from Step 1 into this formula.
Step 3: Determine the emf at the generator end of the lines. The total voltage drop across the transmission lines is given by \( V_{drop} = I \cdot R \). Add this voltage drop to the delivered voltage \( V_{rms} \) to find the emf: \( V_{generator} = V_{rms} + V_{drop} \).
Step 4: Calculate the total power generated by the generator. The total power is the sum of the power delivered to the town and the power lost in the transmission lines: \( P_{total} = P + P_{loss} \).
Step 5: Find the fraction of power wasted in the transmission lines. This is given by \( \text{Fraction wasted} = \frac{P_{loss}}{P_{total}} \). Substitute the values of \( P_{loss} \) and \( P_{total} \) from the previous steps to compute this fraction.

Risposta video verificata per un problema simile:

Questa soluzione video è stata consigliata dai nostri tutor come utile per risolvere questo problema.
Durata del video:
5m

Concetti chiave

Ecco i concetti essenziali che devi comprendere per rispondere correttamente alla domanda.

Ohm's Law

Ohm's Law states that the current (I) flowing through a conductor between two points is directly proportional to the voltage (V) across the two points and inversely proportional to the resistance (R) of the conductor. This relationship is expressed as V = IR. Understanding this law is crucial for calculating the voltage drop across the transmission lines due to their resistance.
Video consigliato:
Percorso guidato
03:07
Resistance and Ohm's Law

Power Loss in Resistive Circuits

In electrical circuits, power loss due to resistance can be calculated using the formula P_loss = I^2R, where P_loss is the power lost, I is the current, and R is the resistance. This concept is essential for determining how much power is wasted in the transmission lines, which directly affects the efficiency of power delivery from the generator to the town.
Video consigliato:
Percorso guidato
06:18
Power in Circuits

RMS Voltage

RMS (Root Mean Square) voltage is a way of expressing the effective value of an alternating current (AC) voltage. It represents the equivalent direct current (DC) voltage that would deliver the same power to a load. In this question, the given 45 kV (rms) voltage is critical for calculating the current and subsequently the emf at the generator end.
Video consigliato:
Percorso guidato
07:14
RMS Current and Voltage
Pratica correlata
Domanda del libro di testo

Neon signs require 12 kV for their operation. To operate from a 240-V line, what must be the ratio of secondary to primary turns of the transformer? What would the voltage output be if the transformer were connected in reverse?

1591
views
Domanda del libro di testo

(II) For the electric power transmission system shown in Fig. 29–26, what is the ratio Ns/Np for (a) the step-up transformer, (b) the step-down transformer next to the home?

1668
views
Domanda del libro di testo

A model-train transformer plugs into 120-V ac and draws 0.35 A while supplying 6.5 A to the train.

(a) What voltage is present across the tracks?

(b) Is the transformer step-up or step-down?

1494
views
Domanda del libro di testo

(III) In a circular region, there is a uniform magnetic field B→\(\overrightarrow{B}\) pointing into the page (Fig. 29–56). An xy coordinate system has its origin at the circular region’s center. A free positive point charge +Q = 1.0 μC is initially at rest at a position x = +10 cm on the x axis. If the magnitude of the magnetic field is now decreased at a rate of -0.10 T/s, what force (magnitude and direction) will act on +Q?


1211
views
Domanda del libro di testo

A circular loop of area 12 m² encloses a magnetic field perpendicular to the plane of the loop; its magnitude is B(t) = (8.0 T/s)t. The loop is connected to a 7.5-Ω resistor and a 6.5-pF capacitor in series. When fully charged, how much charge is stored on the capacitor?

1285
views
Domanda del libro di testo

A transformer has 680 turns in the primary coil and 85 in the secondary coil. What kind of transformer is this, and by what factor does it change the voltage? By what factor does it change the current?