Off to Europe! You plan to take your hair dryer to Europe, where the electrical outlets put out 240 V instead of the 120 V seen in the United States. The dryer puts out 1600 W at 120 V. (b) What current will your dryer draw from a European outlet? (c) What resistance will your dryer appear to have when operated at 240 V?
Ch 31: Alternating Current
31장, 문제 35a
A Step-Down Transformer. A transformer connected to a 120 V (rms) ac line is to supply 12.0 V (rms) to a portable electronic device. The load resistance in the secondary is 5.00 Ω. What should the ratio of primary to secondary turns of the transformer be?
검증된 단계별 안내1
Understand the basic principle of a transformer: A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction. It consists of primary and secondary coils. The voltage across these coils is related by the turns ratio.
Identify the given values: The primary voltage \( V_p \) is 120 V (rms), and the secondary voltage \( V_s \) is 12.0 V (rms). The load resistance \( R_s \) in the secondary is 5.00 \( \Omega \).
Use the formula for the turns ratio of a transformer: The turns ratio \( \frac{N_p}{N_s} \) is given by \( \frac{V_p}{V_s} \). This formula relates the primary and secondary voltages to the number of turns in the primary \( N_p \) and secondary \( N_s \) coils.
Substitute the given values into the formula: \( \frac{N_p}{N_s} = \frac{120}{12} \). This will give you the ratio of the number of turns in the primary coil to the number of turns in the secondary coil.
Interpret the result: The calculated turns ratio will tell you how many times more turns the primary coil should have compared to the secondary coil to achieve the desired voltage transformation.

비슷한 문제에 대한 검증된 영상 답변:
이 영상 해법은 위 문제에 도움이 된다고 튜터들이 추천한 것입니다.
영상 길이:
2m도움이 되었나요?
주요 개념
질문에 올바르게 답하기 위해 반드시 이해해야 하는 핵심 개념들은 다음과 같습니다.
Transformer Basics
A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. It consists of primary and secondary coils, and it can either step up or step down voltage levels. The voltage change is determined by the ratio of the number of turns in the primary coil to the number of turns in the secondary coil.
추천 영상:
가이드 코스
Transformers
Turn Ratio
The turn ratio of a transformer is the ratio of the number of turns in the primary coil to the number of turns in the secondary coil. This ratio determines how the input voltage is transformed into the output voltage. For a step-down transformer, the primary coil has more turns than the secondary coil, resulting in a lower output voltage compared to the input voltage.
추천 영상:
가이드 코스
Ratio of energies of cylinder on surface
RMS Voltage
RMS (Root Mean Square) voltage is a measure of the effective value of an alternating current (AC) voltage. It represents the equivalent DC voltage that would deliver the same power to a load. In the context of transformers, RMS values are used to describe both the input and output voltages, ensuring that the power calculations are accurate and consistent.